Challenges in Sample Preparation, Matrix Effects, and Quality Control in CRISPR-Cas12 Diagnostics: Implications for Medical Laboratory Technology
- Maroloan Aruan · Pelita Harapan University
- Jessica Laurelia · Pelita Harapan University
article · 2026 · RADINKA JOURNAL OF HEALTH SCIENCE, vol. 4(2), pp. 756–768 · doi:10.56778/rjhs.v4i2.798
Abstract
CRISPR-Cas12-based molecular diagnostics offer attomolar-level sensitivity and high specificity through trans-cleavage activity, presenting a potential, rapid, and affordable alternative for Point-of-Care Testing (POCT). However, operational challenges across the pre-analytical, analytical, and post-analytical phases continue to hinder the transition to routine clinical service. This narrative review aims to evaluate the challenges related to sample preparation, matrix effects, and quality control in CRISPR-Cas12 diagnostics while examining their implications for the practice of medical laboratory technology. A structured literature search was conducted across four major databases (PubMed, Scopus, DOAJ, and Google Scholar) for open-access publications from 2016–2026, following the SANRA guidelines and the PRISMA 2020 selection flow. The synthesis indicates that extraction-free and one-pot reaction protocols can reduce turnaround time to 30–60 minutes, alleviate the manual pipetting burden on medical laboratory technologists, and minimize the risk of aerosol contamination. Furthermore, interference from biological inhibitors in complex specimens—such as blood, sputum, and urine—can be mitigated by integrating microfluidic partitioning and electrochemical biosensors, without compromising the limit of detection. Testing reliability is further enhanced through the lyophilization of reagents (eliminating reliance on a cold chain), the inclusion of multiplexed internal controls, and the use of calibrated, smartphone-based digital readout systems. The successful clinical implementation of CRISPR-Cas12 diagnostics requires the standardization of a robust, end-to-end workflow suitable for primary healthcare facilities, rather than relying solely on superior analytical performance within a laboratory setting.
Research area
Physical Sciences › Engineering › Biomedical Engineering › Biosensors and Analytical Detection
Citation trail
Newer papers that cite this one. Go forward to find the latest developments and open questions.
You've reached today's free search limit
Without an API key, OpenAlex allows about 100 searches a day. A free API key raises that 10×. Add it to .env.local as OPENALEX_API_KEY. Searches you've already run still work, because results are cached for a day.